Amorphous alloy buried transformer
All categories

Amorphous alloy buried transformer

Retail price
0.0
Market price
0.0
Number of views:
1002
Product serial number
Quantity
-
+
Stock:
1
Number of views:
1002
Product description
Parameters

Product Introduction

Buried Amorphous alloy transformer low energy consumption, is fully sealed tank structure, corrosion resistance, water proof, reliable operation, can be installed in a distribution transformer or the combined transformer pit. As the product is installed in the ground, do not take up surface space, ideal for relatively scarce places such as city commercial district, park landscape and other places.
 
 

Features    Product Characteristic

Environment    Operation Condition

Air tightness Waterproof Well sealed, High waterproof protection

Ambient temperature 40 deg.] C -25 ℃ ﹏ +   Environmental Temperature -25 deg.] C ﹏ +40 deg.] C

High degree of protection without distortion High degree of protection, No deformation

The maximum daily average temperature of + 35 ° C for     Daily Average temperature +35 ° C for

And low temperatures Low temperature design

Shock level: no severe vibration environment   No serious vibration environment

 

Inclination angle: ≦ 3 [deg.]      Angle of Inclination . 3 [deg.]

No fire risk of explosion is mounted, non-corrosive gas       Installation site: no danger of fire and explosion, non-corrosive gases place.

 

Type definition

 

Implementation of standards

.GB1094.1.2;    .IEC76-1:1993; .IEC76-2:1993;

.GB/T25446;    

.JB/T10544;     

.GB/T15164;    .IEC354-1991; IEC76/3-1-1987;

.GB/T10237;    .IEC76/3-1-1987;

 

product structure

 

 

S (B) H15, S (B) H16-MD-type buried amorphous alloy transformer

 

Rated Capacity

Rated Capacity

(KVA)

 

Voltage combination

Voltage combination

 

coupling

Group Connection

Group

 

Short-circuit impedance

Short

circuit

impedance

(%)

 

No-load current

No-load

current

(%)

 

Load loss

No-load

loss

S(B)H15-M.D

(IN)

 

Load loss

No-load

loss

S(B)H16-M.D

(IN)

 

Load loss

Full-load

loss

(IN)

 

Dimensions

Dimension(mm)

 

Center mounting base

Installed base center

 

Total weight

Total  weight (kg)

high pressure

HV (KV)

Tapping range

Tapping range

(%)

Low pressure

LV (KV)

 

L×W×H

 

MXN/4-ФD(mm)

100

6

6.3

6.6

10

10.5

11

 

±5

±2×2.5

0.4

Dyn11

 

Yyn0

 

4

 

0.9

75

58

1580/1500

860×770×1030

550×660/4-Ф14

855

200

0.6

120

90

2730/2600

940×830×1120

660×870/4-Ф14

1350

250

0.6

140

110

3200/3050

1000×870×1170

660×870/4-Ф14

1565

315

0.5

170

130

3830/3650

1120×930×1280

660×870/4-Ф14

1810

400

0.5

200

160

4520/4300

1340×1050×1360

870×1020/-Ф19

2160

500

0.5

240

190

5410/5150

1460 × 1130 × 1440

870 × 1020 / F19

2550

 

note:

1. Our products have reached S16 performance levels.

2. Dimensions, weight are for reference only to the actual subject.

3. When the core is a three-phase three columns, may be employed as needed Yyn0 coupling group.

4. For the amount of capacity of 500kVA and below the three-phase transformer, load loss values in the table above apply to hatched Dyn11 linking group, the value under load loss slash applies Yyn0 coupling group.

5. If the user needs, the loss can use other values also may provide other high-voltage three-phase transformer tap range.

 

 

 